RESEARCH GROUP COMPUTED TOMOGRAPHY

UNIVERSITY OF APPLIED SCIENCES UPPER AUSTRIA - RESEARCH & DEVELOPMENT LTD.

Publikationen

Nachstehend finden Sie die komplette Aufzählung aller Publikationen die bisher von der CT-Forschungsgruppe veröffentlicht wurden. 

Publikationen 2016

[1] J. Weissenböck, A. Bhattacharya, B. Plank, C. Heinzl, J. Kastner, Visual Classification of Braided and Woven Fiber Bundles in X-Ray Computed Tomography scanned Carbon Fiber Reinforced Polymer Specimens, Case Studies in Nondestructive Testing and Evaluation, May 2016

[2] C. Gusenbauer, E. Leiss-Holzinger, S. Senck, K. Mathmann, J. Kastner, S. Hunger, W. Birkfellner - Characterization of medical and biological samples with a Talbot-Lau grating interferometer µXCT in comparison to reference methods - Case Studies in Nondestructive Testing and Evaluation, 2016, doi: 10.1016/j.csndt.2016.02.001

[3] I. Straumit, C. Hahn, E. Winterstein, B. Plank, S. Lomov, M. Wevers - Computation of permeability of a non-crimp carbon textile reinforcement based on X-ray computed tomography images - COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, Vol. 81, No. 1, 2016, pp. 289-295

[4] C. Gusenbauer, M. Reiter, D. Salaberger, J. Kastner - Comparison of Metal Artefact Reduction Algorithms from Medicine Applied to Industrial XCT Applications - Proceedings of 19th World Conference on Non-Destructive Testing, Munich, Germany, 2016

[5] M. Reiter, J. Kastner - Investigation towards simulation-based determination of measurement uncertainties for X-ray computed tomography - Proceedings of 4th International Conference on Image Formation in X-Ray Computed Tomography, Bamberg, Germany, 2016

[6] C. Gusenbauer, S. Hunger, S. Senck, J. Kastner - Characterization of Tooth Samples with a Talbot-Lau Grating Interferometer μXCT Desktop Device - Proceedings of 4th International Conference on Image Formation in X-Ray Computed Tomography, Bamberg, Germany, 2016

[7] M. Reiter, M. Erler, C. Kuhn, C. Gusenbauer, J. Kastner, SimCT: a simulation tool for X-ray imaging, 6th Conference on Industrial Computed Tomography (iCT2016), Wels, Austria, 2016

[8] B. Fröhler, T. Möller, C. Heinzl - GEMSe: Visualization-Guided Exploration of Multi-channel Segmentation Algorithms - Computer Graphics Forum (Proceedings Eurographics Conference on Visualization), Vol. 35, No. 3, Groningen, Netherlands, 2016 (accepted, to be published).

[9] G. Rao, B. Plank, J. Kastner, Comparision of different segmentation methods for porosity evaluation in CFRP-reference samples and comparison with real porosity samples, 6th Conference on Industrial Computed Tomography (iCT2016), Wels, Austria, 2016

[10] J. Kastner (editor) Proceedings of 6th Conference on Industrial Computed Tomography (iCT2016) 2016, 9-12 February 2016, Wels, Austria, www.ndt.net (2016).

[11] J. Kastner, B. Plank, G. Rao, Evaluation of a Testpiece for Porosity in Carbon Fibre Reinforced Polymers, Proceeding 19th World Conference on Non-Destructive Testing (WCNDT2016), 13 - 17 June 2016, Munich, Germany, 2016

[12] B. Plank, R. Helmus, M. Gschwandtner, R. Hinterhölzl, J. Kastner, In-Situ Observation of Bubble Formation in Neat Resin during the Curing Process by Means of X-Ray Computed Tomography, Proceeding 19th World Conference on Non-Destructive Testing (WCNDT2016), 13 - 17 June 2016, Munich, Germany, 2016

[13] S. Senck, D. Salaberger, C. Gusenbauer, B. Plank, B. Plank, G. Rao and J. Kastner, Talbot-Lau grating interferometer XCT for the quantitative characterization of damage in polymers after impact and static tensile testing, Proceeding 19th World Conference on Non-Destructive Testing (WCNDT2016), 13 - 17 June 2016, Munich, Germany, 2016

[14] C. Gusenbauer, M. Reiter, D. Salaberger, and J. Kastner, Comparison of Metal Artefact Reduction Algorithms from Medicine Applied to Industrial XCT Applications, Proceeding 19th World Conference on Non-Destructive Testing (WCNDT2016), 13 - 17 June 2016, Munich, Germany, 2016

[15] G. Rao, B. Plank, C. Heinzl and J. Kastner, Quantitative evaluation of induced porosity reference samples implemented by drill hole in CFRP using XCT and various segmentation parameters, Proceedings 7th European Conference on Composite Materials (ECCM17), 26th - 30th June, 2016, Munich, Germany, 2016

[16] J. Kastner, S. Senck, B. Plank, D. Salaberger, G. Rao, and C. Gusenbauer, Three-dimensional characterization of structure and damage of polymers using Talbot-Lau grating interferometer µ-XCT, Proceedings 7th European Conference on Composite Materials (ECCM17), 26th - 30th June, 2016, Munich, Germany, 2016

Publikationen 2015

[1] S. Senck, F.L. Bookstein, S. Benazzi, J. Kastner, G.W. Weber, Virtual Reconstruction of Modern and Fossil Hominoid Crania: Consequences of Reference Sample Choice, The Anatomical Record, 2015

[2] J. Kastner, B. Plank, D. Salaberger, Application of CT for the characterization of light-weight materials and components, Proceedings 7. Landshuter Lightweight-Confernce, Landshut, Germany, 2015

[3] B. Plank, C. Hannesschläger, V. Revol, J. Kastner - Characterisation of anisotropic fibre orientation in composites by means of X-ray grating interferometry computed tomography - MATERIALS SCIENCE FORUM, Vol. 826, No. 1, 2015, pp. 868-875

[4] C. Gusenbauer, S. Großeiber, B. Harrer, B. Plank, G. Klösch, W. Schützenhöfer, S. Ilie, G. Requena, J. Kastner, Einsatzmöglichkeiten von CT in der Stahlforschung, Proceedings DACH-Tagung, Salzburg, Austria, 11.-13. Mai 2015

[5] J. Kastner, B. Plank, C. Hannesschläger, V. Revol, Talbot-Lau Gitter-Interferometer-Computertomografie für die Charakterisierung von faserverstärkten Kunststoffen, Proceedings DACH-Tagung, Salzburg, Austria, 11.-13. Mai 2015

[6] S. Senck, A. Jäger, M. Aigner, J. M. Grabmair, J. Kastner, Visualization of microbial biofilm in contaminated polymer tubes by X-ray micro-computed tomography and radiocontrast agents, Bio-Film conference 2015

[7] K. Mathmann, C. Heinzl, J. Kastner, Multimodal image analysis for the characterization of complex wheat-dough microstructures, Proceedings 12th International Congress on Engineering and Food (ICEF12), Québec, Canada, June 14-18, 2015

[8] C. Affenzeller, C. Gusenbauer, M. Reiter, J. Kastner, Measurement uncertainty evaluation of an X-ray computed tomography system, Proceedings International Symposium on Digital Radiology and Computed Tomography (DIR 2015), Ghent, Belgium, June 22-25, 2015

[9] J. Kastner, B. Plank, C. Gusenbauer, S. Senck, V. Revol, A. Sasov - Talbot-Lau grating interferometer X-ray computed tomography for the characterization of fibre-reinforced polymers - Proceedings: Digital Industrial Radiology and Computed Tomography (DIR 2015), Ghent, Belgium, 2015, pp. 10

[10] A. Bhattacharya, C. Heinzl, A. Amirkhanov, J. Kastner and R. Wenger, MetaTracts - A Method for Robust Extraction and Visualization of Carbon Fiber Bundles in Fiber Reinforced Composites, Proceedings 8th IEEE Pacific Visualization Symposium (PacificVis 2015), April 14.-17, 2015, Hangzhou, China.

[11] D. Salaberger, J. Kastner, M. Jerabek, P. Hine und T. Koch, Genauigkeitsbetrachtung quantitativer Röntgen-CT Analysen an kurzfaserverstärkten Polymeren, Proceedings of 20th Symposium on Composites - 20. Symposium Verbundwerkstoffe und Werkstoffverbunde, Vienna, 1.-3. Juli 2015

[12] D. Salaberger, P.J. Hine, M. Jerabek and J. Kastner, Assessment of accuracy of fibre orientation measurement using X-ray Computed Tomography, Proceedings ICCM 2015 - International Conference on Composite Materials, Copenhagen, 19-24 July 2015

[13] B. Plank, G. Rao, J. Kastner - Evaluation of CFRP-Reference Samples for Porosity made by Drilling and Comparison with Industrial Porosity Samples by Means of Quantitative X-ray Computed Tomography - Proceedings 7th International Symposium for NDT in Aerospace, Bremen, Germany, 2015, pp. 10

[14] J. Kastner, S. Senck, C. Gusenbauer, B. Plank, C. Hannesschläger, H. Zauner, C. Heinzl, A. Sasov - Three-dimensional characterization of fibre-reinforced polymers using a Talbot-Lau grating interferometer - CT und data fusion methods - XNPIG 2015 3rd Meeting of X-Ray and Neutron Phase Imaging with Gratings, Bethesda, United States of America, 2015

[15] C. Gusenbauer, M. Reiter, J. Kastner, G. Klösch - Detection of Non-Metallic Inclusions in Quenched and Tempered Steel Bars by XCT and after Fatigue Life Testing - steel research international, Volume 87, Issue 3, pp. 386–393 (March 2016)

[16] J. Kastner, B. Plank, C. Heinzl - Advanced X-ray computed tomography methods: High resolution CT, phase contrast CT, quantitative CT and 4DCT - Proceedings: Digital Industrial Radiology and Computed Tomography (DIR 2015), Ghent, Belgium, 2015, pp. 13

[17] C. Heinzl, J. Kastner, M. Firsching, F. Nachtrab, N. Uhlmann, P. Takman, A. Holmberg, M. Krumm, C. Sauerwein, D. Lichau, P. Doux - Laboratory X-ray tomography for non-destructive testing of specimens and materials at the nanoscale - Proceedings: Digital Industrial Radiology and Computed Tomography (DIR 2015), Ghent, Belgium, 2015

[18] H. Zauner, J. Kastner, C. Heinzl - Multimodal Registration and Fusion of Industrial CT Data - Proceedings: Digital Industrial Radiology and Computed Tomography (DIR 2015), Ghent, Belgium, 2015

[19] J. Kastner - CT for nondestructive testnig and materials characterication - 5th CIA-CT Conference and InteraqCT event on ”Industrial Applications of Computed Tomography”, Lyngby, Denmark, Denmark, 2015

[20] S. Senck, J. Kastner, B. Plank, D. Salaberger, C. Gusenbauer - Three-dimensional characterization of polymeric materials using a Talbot-Lau grating interferometer CT - Bruker microCT User Meeting, Bruges, Belgium, 2015

[21] H. Zauner, J. Kastner, D. Salaberger, C. Heinzl - 3D image processing for single fibre characterization by means of XCT - Acta Stereologica, Vol. 1, No. 1, 2015

[22] A. Reh, A. Amirkhanov, C. Heinzl, J. Kastner, E. Gröller - Fuzzy feature tracking: Visual analysis of industrial 4D-XCT data - COMPUTERS & GRAPHICS, Vol. 3, No. 1, 2015, pp. 177-184

[23] B. Fröhler, A. Amirkhanov, J. Kastner, E. Gröller, C. Heinzl - Multimodal Visualization and Analysis of Spectral and Scalar Data - Proceedings of the 9th conference for Austrian universities of applied sciences, Hagenberg, Austria, 2015, pp. 7

[24] C. Hannesschläger, V. Revol, B. Plank, D. Salaberger, J. Kastner - Fibre structure characterisation of injection moulded short fibre-reinforced polymers by X-ray scatter dark field tomography - Case Studies in Nondestructive Testing and Evaluation, Vol. 3, No. 3, 2015, pp. 34-41

[26] D. Salaberger, M. Jerabek, T. Koch, J. Kastner - Consideration of accuracy of quantitative X-ray CT analyses for short-glass-fibre-reinforced polymers - Materials Science Forum, Vol. 825, No. 1, 2015, pp. 907-913

[27] F. Nachtrab, T. Hofmann, C. Speier, M. Firsching, N. Uhlmann, P. Takman, C. Heinzl, A. Holmberg, M. Krumm, C. Sauerwein, Development of a Timepix based detector for the NanoXCT project, Journal of Instrumentation Vol. 10 (Issue 11), pp. 8, November 2015

[28] J. Kastner, C. Heinzl - X-ray computed tomography for non-destructive testing and materials characterization in Integrated Imaging and Vision Techniques for Industrial Inspection (Editors: Z.Liu, H. Ukida, P. Ramuhalli, K. Niel) - Springer, 2015

[29] G. Kain, M. Barbu, K. Richter, B. Plank, G. Tondi , A. Petutschnigg - Use of tree bark as insulation material - FOREST PRODUCTS JOURNAL, Vol. 65, No. 4, 2015, pp. 16-25

[30] J. Charwat-Pessler, M. Musso, A. Petutschnigg, K. Entacher, B. Plank, E. Wernersson, S. Tangl, P. Schuller-Götzburg - A Bone Sample Containing a Bone Graft Substitute Analyzed by Correlating Density Information Obtained by X-ray Micro Tomography with Compositional Information Obtained by Raman Microscopy - MATERIALS SCIENCE, Vol. 8, No. 7, 2015, pp. 3831-3853

[31] G. Kain, J. Charwat-Pessler, M. Barbu, B. Plank, K. Richter, A. Petutschnigg - Analyzing wood bark insulation board structure using X-ray computed tomography and modeling its thermal conductivity by means of finite difference method - JOURNAL OF COMPOSITE MATERIALS, Vol. 0, No. 0, 2015, pp. 12

[32] S. Kleindel, D. Salaberger, C. Hochenauer - Measurement and Numerical Simulation of Void and Warpage in Glass Fiber Reinforced Molded Chunky Parts - INTERNATIONAL POLYMER PROCESSING, Vol. 30, No. 1, 2015, pp. 100-112

Aktuelle Seite: Home